Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Brand Name : FEEO

Model Number : FE-125

Certification : CE/CCC/RoHS

Place of Origin : China

MOQ : 1PC

Payment Terms : L/C, T/T, Western Union

Supply Ability : 5000pcs per week

Delivery Time : 7days

Packaging Details : 120pcs per carton

Standard : EN60898(IEC60898)IEC60947-2

Rated Voltage : 230V/415V 1P

Rated current : 63/80/100/125A

Rated Breaking Capacity : 10KA

Characteristic Curve : B,C,D

Nominal Frequency : 50/60HZ

Max Operating Voltage : >400VAC

Insulation Voltage : >6KV

Uimp : >10KA

Mechanical Life : Not less than 20000 times

Contact Now

FE-125 high breaking capacity circuit breaker is used for AC 50/60HZ, single-pole 230V or two, three, four-pole 415V

circuit for protecting the circuit that overload and short circuit may take place. It can be used in lighting and electric motor

distribution system. Mean while it is applicable to an unfrequented switch over the electric apparatus and lighting circuit

under normal condition. Breaking capacity is up to standard of IEC60947-7 10KA.

Specifications

Rated Voltage 230V/415V AC
Rated Current 63, 80, 100, 125 A
Characteristic Curve B,C,D
No of Pole 1p ,2p,3p,4p
Electrical Life 6000 times
Mechanical Life 20000 times (C.O)
Weight 1P 2P 3P 4P
150 300 450 600

Dimensions

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Over current tripping characteristic

Item Rated Current(A) Initial State Test Current Limited Time Prospective Result Starting State
a In=63 Cold State 1.05In t ≤1h Non-tripping
In>63 Cold State 1.05In t≤2h Non-tripping
b In=63 Hot State 1.3In t<1h Tripping The current rise steadily to a fixed value within 5s
In>63 Hot State 1.3In t<2h Tripping
c In≥63 Cold State 8In t≤0.2s Non-Tripping
12In t<0.2s Tripping

Characteristics Curve

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Current correction values used at different ambient temperatures

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Current correction factor used at different altitudes

Rated Current (A) Different altitude correction factors
≤2000m 2000m~3000m >3000m
63,80,100,125A 1.0 0.9 0.8


Accessories

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Application

Item Code Application Standard
Auxiliary Contacts OF Offer auxiliary signal control auxiliary circuit

IEC60947-5-1

GB14048.5

Alarm Contacts SD Provide an alarm signal when the MCB trip off

IEC60947-2

GB14048.2

Shunt Tripper HDMX It will let the MCB trip off when the operating voltage exceed the rated voltage by 70%~110%

IEC60947-1

GB14048.1

Shunt Tripper + Auxiliary Contact MX+OF Remote break the circuit and let the auxiliary contacts control the circuit

IEC60947-1

GB14048.1

Over/under Voltage Release MV+MN It can peotect the MCB from under / over voltage

IEC60947-2

GB14048.2

Technical Data

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Working Condition

Temperature: -5℃~+40℃

Altitude : under 2000m

Installation : 35mm DIN rail

Dimensions

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker

Rated Voltage 415V 1P IEC60947-2 AC Circuit BreakerRated Voltage 415V 1P IEC60947-2 AC Circuit BreakerRated Voltage 415V 1P IEC60947-2 AC Circuit BreakerRated Voltage 415V 1P IEC60947-2 AC Circuit Breaker


Product Tags:

IEC60947-2 AC Circuit Breaker

      

415V 1P AC Circuit Breaker

      

IEC60947-2 Circuit Breaker 1P

      
Quality Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker for sale

Rated Voltage 415V 1P IEC60947-2 AC Circuit Breaker Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: YUEQING FEEO ELECTRIC CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)